Three numbers are commonly confused when sizing a solar system:
Understanding the difference between these numbers is the first step toward choosing an appropriate solar system.
Collect at least 12 months of utility bills and determine your total annual electricity consumption in kilowatt-hours (kWh).
A full year is useful because electricity use often changes significantly between seasons.
Also consider future changes that could increase or decrease your electricity consumption, such as:
If a major new electrical load is planned, estimate its annual energy use and add it to your historical consumption rather than sizing the system only from past utility bills.
Your solar offset is the percentage of your annual electricity consumption that you expect the solar system to produce over a typical year.
For example, if your home uses 10,000 kWh per year and your solar system is modeled to produce 8,000 kWh per year:
Solar offset = 8,000 ÷ 10,000 = 80%
A solar system does not necessarily need to produce 100% of your annual electricity use.
Consider:
Important: A 100% annual energy offset does not necessarily mean a $0 electric bill. Utilities may charge fixed fees, minimum charges, non-bypassable charges, or different rates for electricity imported from and exported to the grid.
Once you know your target annual solar production, you can estimate the required DC array size.
Required system size (kW DC) = Target annual solar production (kWh) ÷ Expected annual production per installed kW
For example:
If your target production is 12,000 kWh per year and a production model estimates that each installed kW of solar will generate approximately 1,500 kWh per year at your site:
12,000 ÷ 1,500 = 8 kW DC
The preliminary target would therefore be an approximately 8 kW DC solar array.
Do not use one universal “kWh per kW” number for every project. Solar production varies by site.
Factors include:
Tools such as NREL PVWatts can be used for preliminary energy-production estimates. More detailed project-specific modeling may be appropriate when shading or multiple roof orientations are involved.
Once you have a target system size, divide the total system wattage by the wattage of the selected solar module.
Panel count = Target system watts ÷ Module watts
Target solar array:
9,000 watts DC
Selected module:
450 watts
Calculation:
9,000 ÷ 450 = 20 modules
Twenty 450-watt modules would create a:
20 × 450 W = 9,000 W, or 9.0 kW DC array
If the calculation does not result in a whole number, the final design will normally round to a whole number of modules and then recalculate the resulting system size and expected production.
An energy calculation tells you approximately how much solar capacity you want. It does not determine whether that many panels can actually be installed.
The proposed modules must fit within the usable roof or ground-mount area while accounting for:
Roof orientation and shading also affect how much energy each module is expected to produce. DOE notes that rooftop solar potential depends on factors including geographic location, roof orientation, shading, and the PV system selected.
The final panel count must also work with the selected electrical equipment.
Depending on the system design, this can include checking:
Not every item applies to every system.
For example, string-voltage calculations apply to string-inverter designs, while an Enphase microinverter system is instead constrained by microinverter compatibility, AC branch-circuit limits, and other Enphase design requirements.
It is normal for the system size to change during design.
A typical process looks like this:
The final result may be slightly larger or smaller than the original energy target.
Annual kWh of usage determines the energy goal. Solar production modeling estimates the array size needed to meet that goal. The final approved design determines how many panels can actually be installed safely and compliantly.
A preliminary sizing calculation is useful for planning, but the final module count should be based on the completed layout, equipment specifications, electrical design, utility requirements, and approved plans.