Roof Fall Protection for DIY Solar Work

Roof Fall Protection for DIY Solar Work

Falls are among the most serious hazards associated with residential solar installation. A roof that looks manageable from the ground can become hazardous because of slope, loose roofing material, moisture, heat, wind, skylights, roof edges, and the awkward size of solar modules.

Solar installation also reduces the amount of open walking space on the roof as work progresses, which can force people closer to edges, skylights, and other hazards. OSHA specifically identifies these conditions as fall hazards during rooftop solar installation.

Reduce the amount of time spent on the roof

The safest approach is to perform as much work as reasonably possible from the ground.

Complete tasks such as these before climbing onto the roof whenever possible:

  • Review measurements and plans
  • Prepare and organize components
  • Label wiring
  • Stage tools and hardware
  • Assemble permitted components
  • Plan attachment locations
  • Plan material-lifting routes

For steep, high, fragile, tile, metal, or otherwise difficult roofs, consider whether the rooftop work should instead be performed by a qualified roofing or solar contractor.

Scaffolding or an aerial lift may reduce some types of roof exposure when properly selected and used, but these systems have their own setup, training, inspection, and operating requirements. Do not use unfamiliar access equipment without understanding the manufacturer's instructions and applicable safety requirements.

Use a complete fall-protection system

Wearing a harness by itself does not provide fall protection.

A personal fall-protection system must be designed and used as a complete system.

Depending on the application, this may include:

  • A properly fitted full-body harness
  • A compatible lanyard, lifeline, or self-retracting lifeline
  • Appropriate connectors
  • A suitable anchorage
  • Adequate fall clearance
  • Protection against swing-fall hazards
  • A method for maintaining continuous protection where required
  • A rescue plan

OSHA describes a personal fall-arrest system as a combination of a body harness, anchorage, and connector, with other components such as lanyards, lifelines, or deceleration devices used as appropriate.

Understand fall restraint versus fall arrest

These terms describe two different approaches.

Fall restraint is configured so that you cannot reach an edge or other location where a fall could occur.

Fall arrest allows a fall to begin but stops the person before they strike a lower level.

Where properly designed restraint can prevent access to the fall hazard entirely, it can eliminate some of the clearance and fall-arrest concerns associated with an actual fall. OSHA accepts properly configured restraint as a fall-protection method in residential construction and notes that restraint may be preferable where fall clearance is limited.

Do not improvise either type of system.

Use only approved anchorage locations

A fall-protection anchor cannot simply be attached to whatever is convenient.

Do not attach fall-protection equipment to:

  • Plumbing vents
  • Gutters
  • Conduit
  • Solar modules
  • Racking unless the manufacturer specifically approves it as a fall-protection anchorage
  • Roof sheathing alone unless the anchorage system is specifically engineered and installed for that application
  • Pipe or equipment supports
  • Improvised attachment points

The anchorage and its connection to the building must meet the requirements of the fall-protection system being used.

Follow the anchor manufacturer's instructions for:

  • Approved structural attachment
  • Required fasteners
  • Fastener quantity and spacing
  • Compatible roof construction
  • Installation location
  • Number of permitted users
  • Inspection
  • Removal or reuse

OSHA requires fall-arrest anchorages either to meet specified load criteria or to be designed and used as part of a complete fall-arrest system under appropriate supervision.

If you are not certain that an anchorage is installed in an approved structural location, do not connect to it.

Check fall clearance and swing-fall hazards

A fall-arrest system needs enough clear distance below the worker to stop a fall before the person contacts:

  • The ground
  • A lower roof
  • An eave
  • Scaffolding
  • A deck or balcony
  • HVAC equipment
  • Other structures or objects

The required clearance depends on the specific harness, lanyard or self-retracting device, anchorage position, worker position, and equipment manufacturer's instructions.

Anchorage location also affects swing fall. If the anchor is far to one side, a falling person may swing sideways into the building or another obstruction.

OSHA specifically requires consideration of lower-level contact and identifies swing falls as a hazard that must be evaluated.

Plan for rescue before using fall arrest

A fall-arrest system may prevent a person from striking the ground, but the emergency is not necessarily over once the fall has stopped.

A suspended person may be unable to climb back onto the roof or lower themselves safely.

Before beginning work, know:

  • Who will call for emergency assistance
  • How the suspended person can be reached
  • Whether safe self-rescue is realistically possible
  • How rescuers can access the location
  • What equipment would be required

Do not assume that another person standing on the ground will automatically be able to rescue someone suspended from a roof.

OSHA requires prompt rescue after a fall or a means for the worker to rescue themselves in occupational fall-arrest applications.

Ladder and roof-access basics

Use a ladder that is appropriate for the height and task.

Before climbing:

  • Place the ladder on firm, stable, level footing.
  • Position it at the angle specified by the ladder manufacturer.
  • Secure it against unintended movement.
  • Inspect it for damage before use.
  • Face the ladder while climbing.
  • Maintain three points of contact whenever practical.
  • Keep your body between the ladder side rails.
  • Keep the landing area clear.

When a portable ladder is used to access a roof or other upper landing, the side rails should normally extend at least 3 feet above the landing surface. If this cannot be achieved, additional securing and a suitable handhold or grab device may be required.

Pay particular attention to the transition between the ladder and roof. Getting on and off the ladder can be one of the least stable parts of roof access.

Never carry solar modules up a ladder

Do not climb a ladder while carrying a solar module or another large, heavy component.

Solar modules are bulky, catch wind easily, interfere with balance, and prevent normal ladder contact.

Use an appropriate separate material-handling method, such as:

  • A properly designed material hoist
  • Suitable lifting equipment
  • An appropriate staging system
  • Another manufacturer-approved method

OSHA specifically states that workers should not climb ladders while carrying solar panels and recommends lifting equipment where practical.

The same principle applies to other equipment that prevents safe ladder use, including large inverters or batteries.

Treat skylights and roof openings as fall hazards

Do not assume a skylight or translucent roof panel will support your weight.

Treat skylights, roof hatches, and other openings as fall hazards unless they are protected by an appropriate guard, cover, or fall-protection system.

OSHA specifically identifies skylights and roof openings as hazards requiring protection.

Be especially careful as modules are installed because the remaining walking paths may become narrower.

Stop work when roof conditions become unsafe

Do not continue rooftop work when conditions interfere with secure footing, equipment operation, or fall protection.

Stop work when the roof is:

  • Wet
  • Frosted or icy
  • Covered with loose debris
  • Excessively hot
  • Damaged or unstable
  • Subject to wind that makes materials or workers difficult to control

Wind is particularly important when handling solar modules because their large surface area can make them difficult to control.

Do not use a fixed universal wind-speed limit unless one is specified by the applicable equipment or work method. Conditions can become unsafe before a particular numerical threshold is reached.

Protect the roofing surface

Use footwear appropriate for both rooftop work and the roofing material.

Some roofs can be damaged by normal foot traffic, particularly:

  • Clay or concrete tile
  • Slate
  • Wood roofing
  • Certain metal roofs
  • Fragile or deteriorated roofing

Do not assume that a roof that supports normal environmental loads is safe to walk across casually.

Use the roofing manufacturer's instructions and, when necessary, a roofer familiar with the specific roof covering.

Protect people below the work area

Roof safety includes protecting people on the ground.

Establish a controlled area below rooftop work and keep children, pets, visitors, and unnecessary workers out.

Secure or control:

  • Hand tools
  • Fasteners
  • Racking components
  • Modules
  • Packaging
  • Extension cords
  • Other loose materials

Do not leave objects where they can slide or be blown from the roof.

Inspect equipment before use

Before each work session, inspect fall-protection equipment according to the manufacturer's instructions.

Look for conditions such as:

  • Cuts
  • Fraying
  • Abrasion
  • Damaged stitching
  • Cracks
  • Corrosion
  • Bent or damaged hardware
  • Malfunctioning connectors
  • Contamination
  • Damage to lifelines or retracting devices

Do not use damaged equipment.

Fall-protection equipment that has arrested a fall should be removed from service and handled according to the manufacturer's requirements rather than simply being reused. OSHA likewise requires impacted equipment to be removed from service until appropriately evaluated.

Before Anyone Climbs

  • Roof condition and access route have been evaluated.
  • Weather and roof-surface conditions are acceptable.
  • The ladder is appropriate, stable, inspected, and secured.
  • Roof edges, skylights, openings, and other fall hazards are identified.
  • The selected fall-protection method is appropriate for the work.
  • Harness, connectors, lifeline, and anchorage are compatible.
  • Anchorage is installed at an approved structural location.
  • Required fall clearance and swing-fall hazards have been evaluated.
  • Everyone using fall-protection equipment knows how to use it correctly.
  • A realistic rescue plan is in place.
  • Another capable adult is available to assist or obtain emergency help.
  • Modules and other bulky equipment will be lifted separately rather than carried up a ladder.
  • The area below the work has been controlled to protect people from falling objects.

Know when to hire a professional

Roof work is not a good place to learn fall protection through trial and error.

If you cannot confidently select, install, inspect, and correctly use the required roof-access and fall-protection equipment—or if the roof is steep, high, fragile, deteriorated, or unusually complex—hire a qualified roofing or solar contractor for the rooftop portion of the installation.

This article is a general safety overview, not a substitute for fall-protection training or the instructions supplied by your ladder, anchor, harness, lifeline, roofing, or other equipment manufacturers.

OSHA rules cited here apply to employers and employees rather than automatically governing a homeowner working on their own home. They are nevertheless useful technical safety references. Professional installers must comply with the OSHA requirements and any applicable state-plan rules governing their work.